Your position:Home<< Pesticide residue

Pesticide detecting card(Enzyme inhibition)

Pesticide residue detecting card


Num: AC101
Spec: 20 pieces/ box
Details: Determination of pesticide residues in vegetables
Patent No. ZL 03226093.8
Other: Validity: 12 months

           
Details
Pesticide residue detecting card that consists of chromogenic agent and cholinesterase is a kind of enzyme test paper. It can be used in rapid detection of the pesticide residue of organophosphorus and carbamate, which are widely used and with high toxicity. This kind of detecting card has a strong anti-jamming capacity, and could be used independently without other equipment or reagents. And it is easy to use without any professional and technical training. Currently, pesticide residue detecting card that is easy to store and carry has become national standard method (GB/T5009.199-2003), and it is the best test method on the site.

1. Using method
1.1 Integrated detecting method

1.1.1 Select representative sample of vegetable, wipe the dirt on the surface of sample and then cut the sample into small pieces (about 1cm2), take 5g sample into a bottle with cover, add 10mL pure water or buffer solution, then shake up about 50 times and stand it for at least 2 minutes.
1.1.2 Remove the film of pesticide residue detecting card; dip the white pill into the treated solution (prepared in the step 1.1.1). Stand the card for at least 10 minutes for pre-reaction (place the card into thermostat device at 37℃ if possible). Make sure that the surface of the white pill is moist after pre-reaction.
1.1.3 Fold the card in half, pinch the card for 3 minutes (place it into thermostat device for 3 minutes if possible) to let the white pill and the red pill superimpose for reaction. Judge the results according to the color variation of the white pill.
1.1.4 There should be a blank control test with pure water or buffer solution each time.

1.2 Surface detecting method
1.2.1 Wipe the dirt on the surface of vegetable. Add 2~3 drops of eluant on the surface of the sample, and then use another piece of vegetable to rub gently the part of the sample which is added eluant.
1.2.2 Remove the film of pesticide residue detecting card, and drip the eluate of the samples onto the white pill.
1.2.3 Stand the card for at least 10 minutes for pre-reaction (place the card into thermostat device at 37℃ for 10 minutes if possible). Make sure that the surface of the white pill is moist after pre-reaction.
1.2.4 Fold the card in half, then pinch the card for 3 minutes (place it into thermostat device for 3 minutes if possible) to superimpose the white pill on the red pill for reaction. Judge the results according to the color variation of the white pill.
1.2.5 There should be a blank control test with eluant each time.

2. Results determination
Compared with blank control test, it is positive result that the white pill does not change the color or it turns light blue. It indicates there is a high pesticide residue that the white pill does not change the color. And it indicates there is a relatively low pesticide residue that the white pill turns light blue. While it is negative result that the white pill turns azure or has the same color with blank control test card.

3. Lowest detection limit
The lowest detection limits of pesticide residue detecting card to several commonly used pesticides are as follows (Unit: mg/kg):

Results come from the GC test of Inspection Institutes such as Ministry of Health, Institute of Food Hygiene Supervision and Inspection, and Institute of Product Quality Supervision Inspection in Beijing.
 
4. Supplemental explanation
4.1 There are a lot of secondary metabolites in plants such as scallion, garlic, radish, Chinese chive, celery, coriander, zizania latifolia, mushroom and tomato, which could result in false positive. Also, high chlorophyll vegetables could lead to pigment interference. It is recommended to soak entire vegetable leaves or adopt surface detecting method when dealing with these vegetables.
4.2 Reaction rate slows down when the temperature is below 37℃, so the reaction time should be extended accordingly when adding treated solution on the white pill. It is comparable only when samples detecting card and blank control detecting card have the same reaction time. There are two reasons for color invariable of the blank control detecting card. First, too little buffer solution was added onto the surface of the white pill or pill wasn't moist enough after pre-reaction; second, the temperature was too low.
4.3 Pesticide detecting card is so sensitive to the pesticide that the card wouldn't turn blue if there is small amount of pesticide attached to operators or apparatus.
4.4 Three minutes would be the right time for the reaction when white pill superimpose red pill. The blue color would become increasingly deeper after 3 minutes, and the color fades away after 24h.

5. Retention period
It should be placed in the shade and dry environment without light. It is better to place in the refrigerator at 4℃ temperature. Pesticide residue detecting card which is open should be exhausted within 3 days, if it can’t be exhausted at a time, place it in the dry container and exhaust it within one week. The expiration time is one year.